STRETCH®
TechnicalPolyester

Fire safety.

Cold-mounted polyester membrane — a very matte, seamless ceiling tensioned by hand.

The polyester membrane is classified B-s1,d0 to EN 13501-1 — flame-retardant, with very limited smoke and no flaming droplets. A non-combustible A2-s1,d0 version is available where the strictest fire requirements apply.

Standard classificationB-s1,d0
Non-combustible optionA2-s1,d0
Smoke productions1 — very limited
Flaming dropletsd0 — none
Test standardEN 13501-1

The classification B-s1,d0 means the membrane is flame-retardant (B), produces very little smoke (s1) and releases no burning droplets (d0) — the combination most public and commercial interiors require.

For escape routes, high-rise buildings, hospitals and other projects where a non-combustible lining is specified, the A2-s1,d0 version meets that higher requirement while keeping the same seamless, very matte appearance.

Reaction-to-fire certificates and declarations of performance are available on request for inclusion in your fire dossier.

Need a hand with the specification?

Our specialists help architects and contractors get the detail right — usually within two working days.